Nxp-semiconductors PCA9665 Uživatelský manuál Strana 47

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 91
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 46
xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxx x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xx xx
xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxx x x
xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxx xxx
PCA9665_2 © NXP B.V. 2006. All rights reserved.
Product data sheet Rev. 02 — 7 December 2006 47 of 91
NXP Semiconductors
PCA9665
Fm+ parallel bus to I
2
C-bus controller
C8h BC[6:0] bytes in
I2CDAT have been
transmitted
(AA = 0);
ACK has been
received
No I2CDAT action
or
X X 0 X 0 0 1 Switched to not addressed slave mode;
No recognition of own slave address;
General Call address recognized if GC = 1.
No I2CDAT action
or
X X 0 X 0 1 1 Switched to slave mode; Own slave address
will be recognized; General Call address
recognized if GC = 1.
No I2CDAT action
or
X X 1 X 0 0 1 Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if
GC = 1; A START condition will be
transmitted when the bus becomes free.
No I2CDAT action X X 1 X 0 1 1 Switched to slave mode; Own slave address
will be recognized; General Call address will
be recognized if GC = 1; A START condition
will be transmitted when the bus becomes
free.
Table 41. Slave Transmitter Buffered mode (MODE = 1)
…continued
Status
code
(I2CSTA)
Status of the
I
2
C-bus and the
PCA9665
Application software response Next action taken by the PCA9665
To/from I2CDAT To/from I2CCOUNT To I2CCON
LB BC[6:0] STA STO SI AA MODE