Nxp-semiconductors P89LPC9321 UM10310 Uživatelský manuál Strana 86

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 139
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 85
UM10310 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2010. All rights reserved.
User manual Rev. 2 — 1 November 2010 86 of 139
NXP Semiconductors
UM10310
P89LPC9321 User manual
Table 78. SPI Control register (SPCTL - address E2h) bit description
Bit Symbol Description
0 SPR0 SPI Clock Rate Select
SPR1, SPR0:
00 —
CCLK
4
01 —
CCLK
16
10 —
CCLK
64
11
CCLK
128
1 SPR1
2 CPHA SPI Clock PHAse select (see Figure 42 to Figure 45):
1 — Data is driven on the leading edge of SPICLK, and is sampled on the trailing
edge.
0 — Data is driven when SS
is low (SSIG = 0) and changes on the trailing edge of
SPICLK, and is sampled on the leading edge. (Note: If SSIG = 1, the operation is
not defined.
3 CPOL SPI Clock POLarity (see Figure 42
to Figure 45):
1 — SPICLK is high when idle. The leading edge of SPICLK is the falling edge and
the trailing edge is the rising edge.
0 — SPICLK is low when idle. The leading edge of SPICLK is the rising edge and
the trailing edge is the falling edge.
4 MSTR Master/Slave mode Select (see Table 82).
5 DORD SPI Data ORDer.
1 — The LSB of the data word is transmitted first.
0 — The MSB of the data word is transmitted first.
6 SPEN SPI Enable.
1 — The SPI is enabled.
0 — The SPI is disabled and all SPI pins will be port pins.
7 SSIG SS IGnore.
1 — MSTR (bit 4) decides whether the device is a master or slave.
0 — The SS
pin decides whether the device is master or slave. The SS pin can be
used as a port pin (see Table 82
).
Table 79. SPI Status register (SPSTAT - address E1h) bit allocation
Bit 7 6 5 4 3 2 1 0
SymbolSPIFWCOL------
Reset00xxxxxx
Table 80. SPI Status register (SPSTAT - address E1h) bit description
Bit Symbol Description
0:5 - reserved
6 WCOL SPI Write Collision Flag. The WCOL bit is set if the SPI data register, SPDAT, is
written during a data transfer (see Section 12.5 “
Write collision). The WCOL flag
is cleared in software by writing a logic 1 to this bit.
7 SPIF SPI Transfer Completion Flag. When a serial transfer finishes, the SPIF bit is set
and an interrupt is generated if both the ESPI (IEN1.3) bit and the EA bit are set. If
SS
is an input and is driven low when SPI is in master mode, and SSIG = 0, this bit
will also be set (see Section 12.4 “
Mode change on SS). The SPIF flag is cleared
in software by writing a logic 1 to this bit.
Zobrazit stránku 85